TU1000/92

Material

TU1000/92

60.2 Classic Soapstone

Efficiency

88 %

Maximum amount of wood, lbs

39 kg

Heated area, sq ft

300-750

Material

TU1000/92

60.2 Classic Soapstone

Efficiency

88 %

Maximum amount of wood, lbs

39 kg

Heated area, sq ft

300-750

Technical specifications

TU1000/92

Chimney connection base

Dimensions (measurements on drawings below are in millimeters)

Width (inches) 33.1
Depth (inches) 18.9
Height (inches) 60.2
Weight (pounds) 2690
Firebox width (inches) 12.2
Firebox depth (inches) 9.6

Heating performance

Energy class A+
Heated area, sq ft (depending on heating requirements) 300-750
Nominal heat output, kW 1.9
Efficiency % LHV 88
Maximum load of wood per 24 hours, lbs 39
Heat release time at 100%, in hours (this is how long the heater stays at its hottest) 1.9
Heat release time at 50%, in hours (this how long the heater stays above 50% of its hottest) 10.7
Heat release time at 25%, in hours (this how long the heater stays above 25% of its hottest; aka T25) 18.1

Safety distances to combustibles

Safety distance, back, inches (can be reduced to 3" with a UL/ULC specified heat shield) 20
Safety distance, sides, inches (can be reduced to 3" with a UL/ULC specified heat shield) 14
Safety distance, top (inches) 10
Safety distance, front (inches) 48

Chimney connection and combustion air information

Recommended flue diameter, inches 6-7

TU1000T/92

Top Connection

Dimensions (measurements on drawings below are in millimeters)

Width (inches) 33.1
Depth (inches) 18.9
Height (inches) 60.2
Weight (pounds) 2690
Firebox width (inches) 12.2
Firebox depth (inches) 9.6

Heating performance

Energy class A+
Heated area, sq ft (depending on heating requirements) 300-750
Nominal heat output, kW 1.9
Efficiency % LHV 88
Maximum load of wood per 24 hours, lbs 39
Heat release time at 100%, in hours (this is how long the heater stays at its hottest) 1.9
Heat release time at 50%, in hours (this how long the heater stays above 50% of its hottest) 10.7
Heat release time at 25%, in hours (this how long the heater stays above 25% of its hottest; aka T25) 18.1

Safety distances to combustibles

Safety distance, back, inches (can be reduced to 3" with a UL/ULC specified heat shield) 20
Safety distance, sides, inches (can be reduced to 3" with a UL/ULC specified heat shield) 14
Safety distance, top (inches) 10
Safety distance, front (inches) 48

Chimney connection and combustion air information

Recommended flue diameter, inches 6-7

Instructions & files

User manual Download
DXF Footprint (for architects) Download
Energy class Download