Technical information

Height

Dimensions

Width, mm 930
Depth, mm 690
Height, mm 1950

Heat technology

Energy sign A+
Area to be heated, m2 40-100
Energy intensity, kWh 60.5
Nominal power (min-max), kW 2,4
Efficiency, % 86
CO, mg/Nm3 1125
Particles, mg/Nm3 24
OGC, mg/Nm3 26
NOx, mg/Nm3 125
Maximum amount of wood, kg 16.2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 5.7
Heat release time (h) 50% 20.4
Heat release time (h) 25% 31.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 100
Safety distances side, mm 200
Safety distances up, mm 250
Safety distances front, mm 1000

Chimney connection and combustion air information

Chimney recommendation, ø mm 175…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 331
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 23,9

Supplies

Electrical resistors Option
Cooking products Option

Dimensions

Width, mm 930
Depth, mm 690
Height, mm 1950

Heat technology

Energy sign A+
Area to be heated, m2 40-100
Energy intensity, kWh 60.5
Nominal power (min-max), kW 2,4
Efficiency, % 86
CO, mg/Nm3 1125
Particles, mg/Nm3 24
OGC, mg/Nm3 26
NOx, mg/Nm3 125
Maximum amount of wood, kg 16.2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 5.7
Heat release time (h) 50% 20.4
Heat release time (h) 25% 31.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 100
Safety distances side, mm 200
Safety distances up, mm 250
Safety distances front, mm 1000

Chimney connection and combustion air information

Chimney recommendation, ø mm 175…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 331
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 23,9

Supplies

Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)