Technical information

Height

Dimensions

Width, mm 900
Depth, mm 585
Height, mm 1650
Weight, kg 1450
Firebox width, mm 360
Firebox depth, mm 310

Heat technology

Energy sign A
Area to be heated, m2 40-90
Energy intensity, kWh 41.7
Nominal power (min-max), kW 2.5
Efficiency, % 80
CO, mg/Nm3 875
Particles, mg/Nm3 28
OGC, mg/Nm3 71
NOx, mg/Nm3 145
Maximum amount of wood, kg 12.2
Length of firewood, mm 330 (200-330)
Heat release time (h) 100% 3.9
Heat release time (h) 50% 13.4
Heat release time (h) 25% 21.3
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 150
Safety distances side, mm 150
Safety distances up, mm 250
Safety distances front, mm 1000

Chimney connection and combustion air information

Chimney recommendation, ø mm 175...210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 326
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 30,7

Supplies

Ignition damper Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 900
Depth, mm 585
Height, mm 1650
Weight, kg 1450
Firebox width, mm 360
Firebox depth, mm 310

Heat technology

Energy sign A
Area to be heated, m2 40-90
Energy intensity, kWh 41.7
Nominal power (min-max), kW 2.6
Efficiency, % 80
CO, mg/Nm3 875
Particles, mg/Nm3 28
OGC, mg/Nm3 71
NOx, mg/Nm3 145
Maximum amount of wood, kg 12.2
Length of firewood, mm 330 (200-330)
Heat release time (h) 100% 3.9
Heat release time (h) 50% 13.4
Heat release time (h) 25% 21.3
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 150
Safety distances side, mm 150
Safety distances up, mm 250
Safety distances front, mm 1000

Chimney connection and combustion air information

Chimney recommendation, ø mm 175...210
Top connection, mm 175
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 176
Max. flue gas temperature °C 279
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 211
Flue gas mass flow, g/s 30,7

Supplies

Electrical resistors Option
Cooking products Option