Lampo S 18
Top connectionWidth, mm | 630 |
Depth, mm | 550 |
Height, mm | 1845 |
Weight, kg | 1100 |
Firebox width, mm | 320 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 30-50 |
Energy intensity, kWh | 27.6 |
Nominal power (min-max), kW | 1,6 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1000 |
Particles, mg/Nm3 | 30 |
OGC, mg/Nm3 | 59 |
NOx, mg/Nm3 | 138 |
Maximum amount of wood, kg | 8 |
Length of firewood, mm | 250 (200-330) |
Maximum amount of pellets, kg | 6.7 |
Heat release time (h) 100% | 5.6 |
Heat release time (h) 50% | 17.5 |
Heat release time (h) 25% | 25.5 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (150) |
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1100 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 190 |
Max. flue gas temperature °C | 298 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 228 |
Flue gas mass flow, g/s | 25,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Lampo S 18
Top connectionWidth, mm | 630 |
Depth, mm | 550 |
Height, mm | 1845 |
Weight, kg | 1100 |
Firebox width, mm | 320 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 30-50 |
Energy intensity, kWh | 27.6 |
Nominal power (min-max), kW | 1,6 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1000 |
Particles, mg/Nm3 | 30 |
OGC, mg/Nm3 | 59 |
NOx, mg/Nm3 | 138 |
Maximum amount of wood, kg | 8 |
Length of firewood, mm | 250 (200-330) |
Maximum amount of pellets, kg | 6.7 |
Heat release time (h) 100% | 5.6 |
Heat release time (h) 50% | 17.5 |
Heat release time (h) 25% | 25.5 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (150) |
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1100 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 190 |
Max. flue gas temperature °C | 298 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 228 |
Flue gas mass flow, g/s | 25,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Lampo S 18
Top connectionWidth, mm | 630 |
Depth, mm | 550 |
Height, mm | 1845 |
Weight, kg | 1100 |
Firebox width, mm | 320 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 30-50 |
Energy intensity, kWh | 27.6 |
Nominal power (min-max), kW | 1,6 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1000 |
Particles, mg/Nm3 | 30 |
OGC, mg/Nm3 | 59 |
NOx, mg/Nm3 | 138 |
Maximum amount of wood, kg | 8 |
Length of firewood, mm | 250 (200-330) |
Maximum amount of pellets, kg | 6.7 |
Heat release time (h) 100% | 5.6 |
Heat release time (h) 50% | 17.5 |
Heat release time (h) 25% | 25.5 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (150) |
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1100 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 190 |
Max. flue gas temperature °C | 298 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 228 |
Flue gas mass flow, g/s | 25,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Lampo S 18
Top connectionWidth, mm | 630 |
Depth, mm | 550 |
Height, mm | 1845 |
Weight, kg | 1100 |
Firebox width, mm | 320 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 30-50 |
Energy intensity, kWh | 27.6 |
Nominal power (min-max), kW | 1,6 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1000 |
Particles, mg/Nm3 | 30 |
OGC, mg/Nm3 | 59 |
NOx, mg/Nm3 | 138 |
Maximum amount of wood, kg | 8 |
Length of firewood, mm | 250 (200-330) |
Maximum amount of pellets, kg | 6.7 |
Heat release time (h) 100% | 5.6 |
Heat release time (h) 50% | 17.5 |
Heat release time (h) 25% | 25.5 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (150) |
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1100 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 190 |
Max. flue gas temperature °C | 298 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 228 |
Flue gas mass flow, g/s | 25,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Lampo S 21
Top connectionWidth, mm | 630 |
Depth, mm | 550 |
Height, mm | 2145 |
Weight, kg | 1300 |
Firebox width, mm | 320 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34.5 |
Nominal power (min-max), kW | 1,6 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1000 |
Particles, mg/Nm3 | 30 |
OGC, mg/Nm3 | 59 |
NOx, mg/Nm3 | 138 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 250 (200-330) |
Maximum amount of pellets, kg | 8.3 |
Heat release time (h) 100% | 5.6 |
Heat release time (h) 50% | 17.5 |
Heat release time (h) 25% | 25.5 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (150) |
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1100 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 190 |
Max. flue gas temperature °C | 298 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 228 |
Flue gas mass flow, g/s | 25,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Lampo S 21
Top connectionWidth, mm | 630 |
Depth, mm | 550 |
Height, mm | 2145 |
Weight, kg | 1300 |
Firebox width, mm | 320 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34.5 |
Nominal power (min-max), kW | 1,6 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1000 |
Particles, mg/Nm3 | 30 |
OGC, mg/Nm3 | 59 |
NOx, mg/Nm3 | 138 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 250 (200-330) |
Maximum amount of pellets, kg | 8.3 |
Heat release time (h) 100% | 5.6 |
Heat release time (h) 50% | 17.5 |
Heat release time (h) 25% | 25.5 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (150) |
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1100 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 190 |
Max. flue gas temperature °C | 298 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 228 |
Flue gas mass flow, g/s | 25,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Lampo S 21
Top connectionWidth, mm | 630 |
Depth, mm | 550 |
Height, mm | 2145 |
Weight, kg | 1300 |
Firebox width, mm | 320 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34.5 |
Nominal power (min-max), kW | 1,6 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1000 |
Particles, mg/Nm3 | 30 |
OGC, mg/Nm3 | 59 |
NOx, mg/Nm3 | 138 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 250 (200-330) |
Maximum amount of pellets, kg | 8.3 |
Heat release time (h) 100% | 5.6 |
Heat release time (h) 50% | 17.5 |
Heat release time (h) 25% | 25.5 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (150) |
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1100 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 190 |
Max. flue gas temperature °C | 298 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 228 |
Flue gas mass flow, g/s | 25,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Lampo S 21
Top connectionWidth, mm | 630 |
Depth, mm | 550 |
Height, mm | 2145 |
Weight, kg | 1300 |
Firebox width, mm | 320 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34.5 |
Nominal power (min-max), kW | 1,6 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1000 |
Particles, mg/Nm3 | 30 |
OGC, mg/Nm3 | 59 |
NOx, mg/Nm3 | 138 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 250 (200-330) |
Maximum amount of pellets, kg | 8.3 |
Heat release time (h) 100% | 5.6 |
Heat release time (h) 50% | 17.5 |
Heat release time (h) 25% | 25.5 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (150) |
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1100 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 190 |
Max. flue gas temperature °C | 298 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 228 |
Flue gas mass flow, g/s | 25,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |