Raita S 2D 21
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1100 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 40,9 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 82 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 21
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1100 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 40,9 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 82 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 18
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1280 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34,1 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 8,3 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 21
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1100 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 40,9 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 82 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 18
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1280 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34,1 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 8,3 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 21
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1100 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 40,9 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 82 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 18
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1280 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34,1 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 8,3 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 18
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1280 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34,1 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 8,3 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 18
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 920 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34,1 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 8,3 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 18
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 920 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34,1 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 8,3 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 18
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 920 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34,1 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 8,3 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 18
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 920 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34,1 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 8,3 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 18
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 920 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-60 |
Energy intensity, kWh | 34,1 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 83 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 10 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 8,3 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 21
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1470 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 40,9 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 82 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 21
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1470 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 40,9 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 82 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 21
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1470 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 40,9 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 82 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 21
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1470 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 40,9 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 82 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Raita S 2D 21
Top connectionWidth, mm | 800 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1100 |
Firebox width, mm | 470 |
Firebox depth, mm | 490 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 40,9 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 82 |
CO, mg/Nm3 | 1250 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 39 |
NOx, mg/Nm3 | 149 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 1,1 |
Heat release time (h) 50% | 10,1 |
Heat release time (h) 25% | 18,2 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances side, mm | 50 (150) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1400 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 206 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 247 |
Flue gas mass flow, g/s | 31,5 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |