Raita 15
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1500 |
Weight, kg | 1120 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 41,9 |
Nominal power (min-max), kW | 1,9 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 33 |
OGC, mg/Nm3 | 66 |
NOx, mg/Nm3 | 137 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 6,1 |
Heat release time (h) 50% | 18,1 |
Heat release time (h) 25% | 28,8 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (100) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 167 |
Max. flue gas temperature °C | 289 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 200 |
Flue gas mass flow, g/s | 22,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1260 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 2010 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 15
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1500 |
Weight, kg | 1120 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 41,9 |
Nominal power (min-max), kW | 1,9 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 33 |
OGC, mg/Nm3 | 66 |
NOx, mg/Nm3 | 137 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 6,1 |
Heat release time (h) 50% | 18,1 |
Heat release time (h) 25% | 28,8 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (100) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 167 |
Max. flue gas temperature °C | 289 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 200 |
Flue gas mass flow, g/s | 22,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1260 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1460 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 18
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1840 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1260 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1460 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 18
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1840 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1260 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1460 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 18
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1840 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 21
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 2180 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1460 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 18
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1840 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 21
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 2180 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1460 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 18
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1360 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 21
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 2180 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 18
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1360 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 21
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 2180 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 18
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1360 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 21
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1610 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 15
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1500 |
Weight, kg | 1500 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 41,9 |
Nominal power (min-max), kW | 1,9 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 33 |
OGC, mg/Nm3 | 66 |
NOx, mg/Nm3 | 137 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 6,1 |
Heat release time (h) 50% | 18,1 |
Heat release time (h) 25% | 28,8 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (100) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 167 |
Max. flue gas temperature °C | 289 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 200 |
Flue gas mass flow, g/s | 22,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 18
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1360 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 21
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1610 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 15
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1500 |
Weight, kg | 1500 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 41,9 |
Nominal power (min-max), kW | 1,9 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 33 |
OGC, mg/Nm3 | 66 |
NOx, mg/Nm3 | 137 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 6,1 |
Heat release time (h) 50% | 18,1 |
Heat release time (h) 25% | 28,8 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (100) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 167 |
Max. flue gas temperature °C | 289 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 200 |
Flue gas mass flow, g/s | 22,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 18
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1360 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 21
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1610 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 15
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1500 |
Weight, kg | 1500 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 41,9 |
Nominal power (min-max), kW | 1,9 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 33 |
OGC, mg/Nm3 | 66 |
NOx, mg/Nm3 | 137 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 6,1 |
Heat release time (h) 50% | 18,1 |
Heat release time (h) 25% | 28,8 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (100) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 167 |
Max. flue gas temperature °C | 289 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 200 |
Flue gas mass flow, g/s | 22,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1740 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 21
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1610 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 15
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1500 |
Weight, kg | 1500 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 41,9 |
Nominal power (min-max), kW | 1,9 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 33 |
OGC, mg/Nm3 | 66 |
NOx, mg/Nm3 | 137 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 6,1 |
Heat release time (h) 50% | 18,1 |
Heat release time (h) 25% | 28,8 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (100) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 167 |
Max. flue gas temperature °C | 289 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 200 |
Flue gas mass flow, g/s | 22,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Electrical resistors | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1740 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 21
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 1610 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Raita 15
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1500 |
Weight, kg | 1120 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 41,9 |
Nominal power (min-max), kW | 1,9 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 33 |
OGC, mg/Nm3 | 66 |
NOx, mg/Nm3 | 137 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 6,1 |
Heat release time (h) 50% | 18,1 |
Heat release time (h) 25% | 28,8 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (100) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 167 |
Max. flue gas temperature °C | 289 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 200 |
Flue gas mass flow, g/s | 22,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1740 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 2010 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 15
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1500 |
Weight, kg | 1120 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 41,9 |
Nominal power (min-max), kW | 1,9 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 33 |
OGC, mg/Nm3 | 66 |
NOx, mg/Nm3 | 137 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 6,1 |
Heat release time (h) 50% | 18,1 |
Heat release time (h) 25% | 28,8 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (100) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 167 |
Max. flue gas temperature °C | 289 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 200 |
Flue gas mass flow, g/s | 22,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1740 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 2010 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Raita 15
Connection belowWidth, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1500 |
Weight, kg | 1120 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 50-70 |
Energy intensity, kWh | 41,9 |
Nominal power (min-max), kW | 1,9 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 33 |
OGC, mg/Nm3 | 66 |
NOx, mg/Nm3 | 137 |
Maximum amount of wood, kg | 12 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 10 |
Heat release time (h) 100% | 6,1 |
Heat release time (h) 50% | 18,1 |
Heat release time (h) 25% | 28,8 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (100) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 150 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 167 |
Max. flue gas temperature °C | 289 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 200 |
Flue gas mass flow, g/s | 22,3 |
Supplies |
|
P10-Pellet system | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 1800 |
Weight, kg | 1260 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 55-80 |
Energy intensity, kWh | 52,6 |
Nominal power (min-max), kW | 2,0 |
Efficiency, % | 84 |
CO, mg/Nm3 | 1021 |
Particles, mg/Nm3 | 35 |
OGC, mg/Nm3 | 53 |
NOx, mg/Nm3 | 139 |
Maximum amount of wood, kg | 15 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 6,4 |
Heat release time (h) 50% | 19,9 |
Heat release time (h) 25% | 33,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 175 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 210 |
Flue gas mass flow, g/s | 23,4 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |
Width, mm | 1100 |
Depth, mm | 550 |
Height, mm | 2100 |
Weight, kg | 2010 |
Firebox width, mm | 470 |
Firebox depth, mm | 345 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 60-90 |
Energy intensity, kWh | 67,7 |
Nominal power (min-max), kW | 2,1 |
Efficiency, % | 85 |
CO, mg/Nm3 | 875 |
Particles, mg/Nm3 | 38 |
OGC, mg/Nm3 | 35 |
NOx, mg/Nm3 | 143 |
Maximum amount of wood, kg | 19 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 15 |
Heat release time (h) 100% | 6,7 |
Heat release time (h) 50% | 22,4 |
Heat release time (h) 25% | 39,1 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 20 (250) |
Safety distances side, mm | 50 (100) |
Safety distances up, mm | 100 (150) |
Safety distances front, mm | 1200 |
Safety distance for uninsulated product shown in parentheses (XX mm) | |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 150…210 |
Top connection, mm | 150 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 183 |
Max. flue gas temperature °C | 230 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 220 |
Flue gas mass flow, g/s | 23,6 |
Supplies |
|
P10-Pellet system | Standard equipment |
Ignition damper | Standard equipment |
Senso fireplace controller | Option |
Cooking products | Option |
Other considerations |
|
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm) |