Lasse

Lasse

1700 Rubbing

Efficiency

74,8 %

Maximum amount of wood

18 kg

Area to be heated

60-110 m2

Energy intensity

58,9 kWh

Lasse

1700 Rubbing

Efficiency

74,8 %

Maximum amount of wood

18 kg

Area to be heated

60-110 m2

Energy intensity

58,9 kWh

Technical specifications

LASSE V1 17

Connection below

Dimensions

Width, mm 970
Depth, mm 985
Height, mm 1700
Weight, kg 1850
Width of the baking oven's firebox, mm 460
Depth of the baking oven's firebox, mm 750

Heat technology

Area to be heated, m2 60-110
Energy intensity, kWh 58,9
Efficiency, % 74,8
Maximum amount of wood, kg 18
Length of firewood, mm 500
Heat release time (h) 100% 8,9
Heat release time (h) 50% 26
Heat release time (h) 25% 41,3

Safety distances

Safety distances back (dR), mm 50
Safety distances side (dS), mm 50
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 160
Average flue gas temperature °C 178
Max. flue gas temperature °C 329
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 214
Flue gas mass flow, g/s 47,0
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Cooking products Optional

LASSE V1 17

Connection below

Dimensions

Width, mm 970
Depth, mm 985
Height, mm 1700
Weight, kg 1850
Width of the baking oven's firebox, mm 460
Depth of the baking oven's firebox, mm 750

Heat technology

Area to be heated, m2 60-110
Energy intensity, kWh 58,9
Efficiency, % 74,8
Maximum amount of wood, kg 18
Length of firewood, mm 500
Heat release time (h) 100% 8,9
Heat release time (h) 50% 26
Heat release time (h) 25% 41,3

Safety distances

Safety distances back (dR), mm 50
Safety distances side (dS), mm 50
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 160
Average flue gas temperature °C 178
Max. flue gas temperature °C 329
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 214
Flue gas mass flow, g/s 47,0
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download