TLU2000/92
Connection belowWidth, mm | 930 |
Depth, mm | 690 |
Height, mm | 1650 |
Weight, kg | 1960 |
Firebox width, mm | 370 |
Firebox depth, mm | 305 |
Width of the baking oven's firebox, mm | 390 |
Depth of the baking oven's firebox, mm | 465 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-100 |
Energy intensity, kWh | 60.5 |
Nominal power (min-max), kW | 2,4 |
Efficiency, % | 86 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 24 |
OGC, mg/Nm3 | 26 |
NOx, mg/Nm3 | 125 |
Maximum amount of wood, kg | 16.2 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 5.7 |
Heat release time (h) 50% | 20.4 |
Heat release time (h) 25% | 31.4 |
Safety distances |
|
Safety distances back, mm | 100 |
Safety distances side, mm | 200 |
Safety distances up, mm | 250 |
Safety distances front, mm | 1000 |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 175…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 161 |
Max. flue gas temperature °C | 331 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 193 |
Flue gas mass flow, g/s | 23,9 |
Supplies |
|
Ignition damper | Option |
P10-Pellet system | Option |
Electrical resistors | Option |
Cooking products | Option |
TLU2000T/92
Top connectionWidth, mm | 930 |
Depth, mm | 690 |
Height, mm | 1950 |
Weight, kg | 2260 |
Firebox width, mm | 370 |
Firebox depth, mm | 305 |
Width of the baking oven's firebox, mm | 390 |
Depth of the baking oven's firebox, mm | 375 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-100 |
Energy intensity, kWh | 60.5 |
Nominal power (min-max), kW | 2,4 |
Efficiency, % | 86 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 24 |
OGC, mg/Nm3 | 26 |
NOx, mg/Nm3 | 125 |
Maximum amount of wood, kg | 16.2 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 5.7 |
Heat release time (h) 50% | 20.4 |
Heat release time (h) 25% | 31.4 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 100 |
Safety distances side, mm | 200 |
Safety distances up, mm | 250 |
Safety distances front, mm | 1000 |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 175…210 |
Top connection, mm | 175 |
Maximum weight of top connection flue, kg | 550 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 161 |
Max. flue gas temperature °C | 331 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 193 |
Flue gas mass flow, g/s | 23,9 |
Supplies |
|
P10-Pellet system | Option |
Electrical resistors | Option |
Cooking products | Option |
TLU2000/92
Connection belowWidth, mm | 930 |
Depth, mm | 690 |
Height, mm | 1950 |
Heat technology |
|
Energy sign | A+ |
Area to be heated, m2 | 40-100 |
Energy intensity, kWh | 60.5 |
Nominal power (min-max), kW | 2,4 |
Efficiency, % | 86 |
CO, mg/Nm3 | 1125 |
Particles, mg/Nm3 | 24 |
OGC, mg/Nm3 | 26 |
NOx, mg/Nm3 | 125 |
Maximum amount of wood, kg | 16.2 |
Length of firewood, mm | 330 (200-330) |
Maximum amount of pellets, kg | 12,5 |
Heat release time (h) 100% | 5.7 |
Heat release time (h) 50% | 20.4 |
Heat release time (h) 25% | 31.4 |
Firewood length can vary between those shown in parentheses (XX mm) | |
Safety distances |
|
Safety distances back, mm | 100 |
Safety distances side, mm | 200 |
Safety distances up, mm | 250 |
Safety distances front, mm | 1000 |
Chimney connection and combustion air information |
|
Chimney recommendation, ø mm | 175…210 |
Fire air intake from under the floor, connection size, ø mm | 150 |
Average flue gas temperature °C | 161 |
Max. flue gas temperature °C | 331 |
Minimum draft of the flue, Pa. | 12 |
Flue gas outlet temperature °C | 193 |
Flue gas mass flow, g/s | 23,9 |
Supplies |
|
P10-Pellet system | Option |
Electrical resistors | Option |
Cooking products | Option |
Other considerations |
|
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm) |