Technical information

Height

Dimensions

Width, mm 1036
Depth, mm 739
Height, mm 1650
Weight, kg 1450
Firebox width, mm 310
Firebox depth, mm 245

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 42.9
Nominal power (min-max), kW 2,0
Efficiency, % 81
CO, mg/Nm3 750
Particles, mg/Nm3 23
OGC, mg/Nm3 69
NOx, mg/Nm3 150
Maximum amount of wood, kg 12
Length of firewood, mm 250 (200-300)
Maximum amount of pellets, kg 8
Heat release time (h) 100% 3.3
Heat release time (h) 50% 16
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 100
Safety distances side, mm 200
Safety distances up, mm 250
Safety distances front, mm 1000

Chimney connection and combustion air information

Chimney recommendation, ø mm 175…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 195
Max. flue gas temperature °C 334
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 234
Flue gas mass flow, g/s 19,7

Supplies

Ignition damper Optional
P10-Pellet system Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1036
Depth, mm 739
Height, mm 1650
Weight, kg 1450
Firebox width, mm 310
Firebox depth, mm 245

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 42.9
Nominal power (min-max), kW 2,0
Efficiency, % 81
CO, mg/Nm3 750
Particles, mg/Nm3 23
OGC, mg/Nm3 69
NOx, mg/Nm3 150
Maximum amount of wood, kg 12
Length of firewood, mm 250 (200-300)
Maximum amount of pellets, kg 8
Heat release time (h) 100% 3.3
Heat release time (h) 50% 16
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 100
Safety distances side, mm 200
Safety distances up, mm 250
Safety distances front, mm 1000

Chimney connection and combustion air information

Chimney recommendation, ø mm 150..180
Top connection, mm 175
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 195
Max. flue gas temperature °C 334
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 234
Flue gas mass flow, g/s 19,7

Supplies

Electrical resistors Optional
P10-Pellet system Optional
Cooking products Optional