Technical information

Height

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1690

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1690

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1690

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1690

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1270

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1600

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1600

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1600

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1600

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1180

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1180

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1180

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1180

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1180

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,8
Efficiency, % 82
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 48
NOx, mg/Nm3 157
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2050

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2050

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2050

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2050

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1540

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1540

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1540

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1540

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1540

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1910

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1910

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1910

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1910

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1390

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1390

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1390

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1390

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1390

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 59.4
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 157
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 7.8
Heat release time (h) 50% 24.4
Heat release time (h) 25% 40.2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 275
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 32,1

Supplies

Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2420

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2420

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2420

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2420

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1810

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1811

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1812

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1813

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1814

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1610

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1610

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1610

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1610

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1610

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 74.9
Nominal power (min-max), kW 2,1
Efficiency, % 87
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 118
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8
Heat release time (h) 50% 25
Heat release time (h) 25% 41
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 161
Max. flue gas temperature °C 254
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 193
Flue gas mass flow, g/s 32,1

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)