Technical information

Height

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1730

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1730

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1730

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1730

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1700

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1700

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1700

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1700

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44.8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13.5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11.2
Heat release time (h) 100% 7.6
Heat release time (h) 50% 23.7
Heat release time (h) 25% 39.4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (250)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2090

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2090

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2090

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2090

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1950

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1950

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1950

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1950

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60.2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17.3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14.3
Heat release time (h) 100% 8.1
Heat release time (h) 50% 26.3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2460

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2460

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2460

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2460

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Option
Electrical resistors Option
Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75.5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17.4
Heat release time (h) 100% 8.5
Heat release time (h) 50% 28.8
Heat release time (h) 25% 48.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (350)
Safety distances side, mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front, mm 1100
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Option
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)