Saramo

Material

Saramo

1500 Structure White Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Nobile Soapstone

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Classic Soapstone

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1500 Satin Black Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Unica Soapstone

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Grafia Soapstone

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1500 Structure Black Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Lux White Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Nobile Soapstone

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

1800 Satin Black Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Satin White Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Unica Soapstone

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

1800 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Structure White Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Lux White Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Classic Soapstone

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

2100 Satin Black Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Satin White Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Grafia Soapstone

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

2100 Structure Black Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Structure White Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Nobile Soapstone

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Satin Black Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Unica Soapstone

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Structure Black Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Lux White Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Classic Soapstone

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Satin Black Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Satin White Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Grafia Soapstone

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Structure White Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Nobile Soapstone

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Satin Black Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Unica Soapstone

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Structure Black Ceramic

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Lux White Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Classic Soapstone

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Material

Saramo

1500 Satin White Ceramic

Efficiency

80 %

Maximum amount of wood

13,5 kg

Area to be heated

60-80 m2

Energy intensity

44,8 kWh

Material

Saramo

1800 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

17,3 kg

Area to be heated

65-90 m2

Energy intensity

60,2 kWh

Material

Saramo

2100 Grafia Soapstone

Efficiency

86 %

Maximum amount of wood

21 kg

Area to be heated

70-100 m2

Energy intensity

75,5 kWh

Technical specifications

Saramo 15

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 18

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 21

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 15

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1730
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 15

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 18

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 21

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 15

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1730
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 15

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 18

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 21

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 15

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1730
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 18

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2090
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 18

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 21

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 15

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1730
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 18

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2090
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 18

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1400
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 21

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 15

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 18

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2090
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 21

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2460
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 21

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 15

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 18

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 2090
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 21

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2460
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 21

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1620
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 15

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 18

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 21

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2460
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 15

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 18

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 21

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2460
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 15

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 18

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 21

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 15

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1700
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 18

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 21

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 15

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1700
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 18

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 21

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 15

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1700
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 18

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1950
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 21

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 15

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1700
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 18

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1950
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 21

Connection below

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 1820
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Saramo 15

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 18

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1950
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 21

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 15

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1500
Weight, kg 1260
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 60-80
Energy intensity, kWh 44,8
Nominal power (min-max), kW 1,2
Efficiency, % 80
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 53
NOx, mg/Nm3 165
Maximum amount of wood, kg 13,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 11,2
Heat release time (h) 100% 7,6
Heat release time (h) 50% 23,7
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 217
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 260
Flue gas mass flow, g/s 28,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 18

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 1800
Weight, kg 1950
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 65-90
Energy intensity, kWh 60,2
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 40
OGC, mg/Nm3 67
NOx, mg/Nm3 165
Maximum amount of wood, kg 17,3
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 14,3
Heat release time (h) 100% 8,1
Heat release time (h) 50% 26,3
Heat release time (h) 25% 44
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (200)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 200
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 188
Max. flue gas temperature °C 284
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 226
Flue gas mass flow, g/s 26,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo 21

Top connection

Dimensions

Width, mm 1250
Depth, mm 550
Height, mm 2100
Weight, kg 2230
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 70-100
Energy intensity, kWh 75,5
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 29
OGC, mg/Nm3 67
NOx, mg/Nm3 110
Maximum amount of wood, kg 21
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 17,4
Heat release time (h) 100% 8,5
Heat release time (h) 50% 28,8
Heat release time (h) 25% 48,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (350)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1100
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 159
Max. flue gas temperature °C 273
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 191
Flue gas mass flow, g/s 24,3
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download