Petro

Material

Petro

1500 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Classic Soapstone

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Grafia Soapstone

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Nobile Soapstone

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Unica Soapstone

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Lux White Ceramic

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Satin White Ceramic

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Structure White Ceramic

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Structure Black Ceramic

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Classic Soapstone

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Grafia Soapstone

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Nobile Soapstone

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Unica Soapstone

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Lux White Ceramic

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Satin White Ceramic

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Structure White Ceramic

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Material

Petro

1500 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

30-50 m2

Energy intensity

32 kWh

Material

Petro

1800 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

11,6 kg

Area to be heated

50-70 m2

Energy intensity

42,7 kWh

Material

Petro

2100 Structure Black Ceramic

Efficiency

90 %

Maximum amount of wood

14,2 kg

Area to be heated

60-80 m2

Energy intensity

53,8 kWh

Technical specifications

Petro 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1310
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1600
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1870
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1310
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1600
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1870
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1310
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1600
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1870
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1310
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1600
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1870
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 990
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1180
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150...180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1370
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 990
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1180
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1370
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 990
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1180
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1370
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 990
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1180
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1370
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm B 370
A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1310
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1600
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1870
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1310
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1600
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1870
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1310
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1600
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1870
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1310
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1600
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1870
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 990
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1180
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150...180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1370
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 990
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1180
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1370
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 990
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1180
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1370
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 15

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 990
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 32
Nominal power (min-max), kW 0,8
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 26
OGC, mg/Nm3 52
NOx, mg/Nm3 156
Maximum amount of wood, kg 9
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 7,2
Heat release time (h) 100% 1,7
Heat release time (h) 50% 24,4
Heat release time (h) 25% 43,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 198
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 238
Flue gas mass flow, g/s 17,6
The dimension of the duct connection opening, mm E 1300
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1180
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 42,7
Nominal power (min-max), kW 0,9
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 26
OGC, mg/Nm3 61
NOx, mg/Nm3 156
Maximum amount of wood, kg 11,6
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 9,4
Heat release time (h) 100% 4,9
Heat release time (h) 50% 27,5
Heat release time (h) 25% 48,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 165
Max. flue gas temperature °C 356
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 198
Flue gas mass flow, g/s 15,9
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Petro 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1370
Firebox width, mm 450
Firebox depth, mm 300

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 53,8
Nominal power (min-max), kW 1
Efficiency, % 90
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 61
NOx, mg/Nm3 91
Maximum amount of wood, kg 14,2
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 11,5
Heat release time (h) 100% 8,2
Heat release time (h) 50% 30,6
Heat release time (h) 25% 53,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (150)
Safety distances side (dS), mm 20 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 800/600
Safety distance to the side on the front of the product (dS2), mm 20/20
Side radiation area (dL), mm 0
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 237
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 14,1
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download