Saramo S

Material

Saramo S

2100 Nobile Soapstone

Efficiency

80 %

Maximum amount of wood

14,5 kg

Area to be heated

55-80 m2

Energy intensity

48,5 kWh

Material

Saramo S

2100 Unica Soapstone

Efficiency

80 %

Maximum amount of wood

14,5 kg

Area to be heated

55-80 m2

Energy intensity

48,5 kWh

Material

Saramo S

2100 Lux White Ceramic

Efficiency

80 %

Maximum amount of wood

14,5 kg

Area to be heated

55-80 m2

Energy intensity

48,5 kWh

Material

Saramo S

2100 Satin White Ceramic

Efficiency

80 %

Maximum amount of wood

14,5 kg

Area to be heated

55-80 m2

Energy intensity

48,5 kWh

Material

Saramo S

2100 Structure White Ceramic

Efficiency

80 %

Maximum amount of wood

14,5 kg

Area to be heated

55-80 m2

Energy intensity

48,5 kWh

Material

Saramo S

2100 Structure Black Ceramic

Efficiency

80 %

Maximum amount of wood

14,5 kg

Area to be heated

55-80 m2

Energy intensity

48,5 kWh

Material

Saramo S

1800 Classic Soapstone

Efficiency

80 %

Maximum amount of wood

12,5 kg

Area to be heated

50-70 m2

Energy intensity

41,8 kWh

Material

Saramo S

1800 Grafia Soapstone

Efficiency

80 %

Maximum amount of wood

12,5 kg

Area to be heated

50-70 m2

Energy intensity

41,8 kWh

Material

Saramo S

1800 Nobile Soapstone

Efficiency

80 %

Maximum amount of wood

12,5 kg

Area to be heated

50-70 m2

Energy intensity

41,8 kWh

Material

Saramo S

1800 Unica Soapstone

Efficiency

80 %

Maximum amount of wood

12,5 kg

Area to be heated

50-70 m2

Energy intensity

41,8 kWh

Material

Saramo S

1800 Lux White Ceramic

Efficiency

80 %

Maximum amount of wood

12,5 kg

Area to be heated

50-70 m2

Energy intensity

41,8 kWh

Material

Saramo S

1800 Satin White Ceramic

Efficiency

80 %

Maximum amount of wood

12,5 kg

Area to be heated

50-70 m2

Energy intensity

41,8 kWh

Material

Saramo S

1800 Structure White Ceramic

Efficiency

80 %

Maximum amount of wood

12,5 kg

Area to be heated

50-70 m2

Energy intensity

41,8 kWh

Material

Saramo S

1800 Structure Black Ceramic

Efficiency

80 %

Maximum amount of wood

12,5 kg

Area to be heated

50-70 m2

Energy intensity

41,8 kWh

Material

Saramo S

2100 Classic Soapstone

Efficiency

80 %

Maximum amount of wood

14,5 kg

Area to be heated

55-80 m2

Energy intensity

48,5 kWh

Material

Saramo S

2100 Grafia Soapstone

Efficiency

80 %

Maximum amount of wood

14,5 kg

Area to be heated

55-80 m2

Energy intensity

48,5 kWh

Technical specifications

Saramo S 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1780
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 55-80
Energy intensity, kWh 48,5
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 14,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1780
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 55-80
Energy intensity, kWh 48,5
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 14,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1240
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 55-80
Energy intensity, kWh 48,5
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 14,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1240
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 55-80
Energy intensity, kWh 48,5
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 14,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1240
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 55-80
Energy intensity, kWh 48,5
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 14,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1240
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 55-80
Energy intensity, kWh 48,5
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 14,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1560
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 50-70
Energy intensity, kWh 41,8
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 12,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1560
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 50-70
Energy intensity, kWh 41,8
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 12,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1560
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 50-70
Energy intensity, kWh 41,8
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 12,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1560
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 50-70
Energy intensity, kWh 41,8
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 12,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1110
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 50-70
Energy intensity, kWh 41,8
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 12,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1110
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 50-70
Energy intensity, kWh 41,8
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 12,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1110
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 50-70
Energy intensity, kWh 41,8
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 12,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1110
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 50-70
Energy intensity, kWh 41,8
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 12,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1600
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1780
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 55-80
Energy intensity, kWh 48,5
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 14,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Saramo S 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1780
Firebox width, mm 620
Firebox depth, mm 345

Heat technology

Energy sign A
Area to be heated, m2 55-80
Energy intensity, kWh 48,5
Nominal power (min-max), kW 1,3
Efficiency, % 80
CO, mg/Nm3 1000
Particles, mg/Nm3 39
OGC, mg/Nm3 45
NOx, mg/Nm3 129
Maximum amount of wood, kg 14,5
Length of firewood, mm 330 (200-500)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 6,6
Heat release time (h) 50% 20,9
Heat release time (h) 25% 36,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (300)
Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1300
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 500
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 214
Max. flue gas temperature °C 445
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 257
Flue gas mass flow, g/s 28,4
The dimension of the duct connection opening, mm E 1900
E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download