Jaani V1

Jaani V1

1800 Rubbing

Efficiency

82 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

39,5 kWh

Jaani V1

2100 Rubbing

Efficiency

82 %

Maximum amount of wood

13,2 kg

Area to be heated

40-80 m2

Energy intensity

46,8 kWh

Jaani V1

2100 Rubbing

Efficiency

82 %

Maximum amount of wood

13,2 kg

Area to be heated

40-80 m2

Energy intensity

46,8 kWh

Jaani V1

1500 Rubbing

Efficiency

79 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

32,2 kWh

Jaani V1

1500 Rubbing

Efficiency

79 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

32,2 kWh

Jaani V1

1800 Rubbing

Efficiency

79 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

39,5 kWh

Jaani V1

1800 Rubbing

Efficiency

79 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

39,5 kWh

Jaani V1

2100 Rubbing

Efficiency

83 %

Maximum amount of wood

13,2 kg

Area to be heated

40-80 m2

Energy intensity

46,8 kWh

Jaani V1

2100 Rubbing

Efficiency

83 %

Maximum amount of wood

13,2 kg

Area to be heated

40-80 m2

Energy intensity

46,8 kWh

Jaani V1

1500 Rubbing

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

32,2 kWh

Jaani V1

1500 Rubbing

Efficiency

83 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

32,2 kWh

Jaani V1

1800 Rubbing

Efficiency

82 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

39,5 kWh

Technical specifications

Jaani T V1 18

Top connection

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 960
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39,5
Nominal power (min-max), kW 1,9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 4,7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2,3
Heat release time (h) 50% 12,9
Heat release time (h) 25% 21,6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 100
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0
The dimension of the duct connection opening, mm E 1540
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Jaani T V1 21

Top connection

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1110
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 46,8
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 13,2
Firewood consumption, kg/h 4,9
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2,6
Heat release time (h) 50% 13,6
Heat release time (h) 25% 24,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 100
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 500
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 164
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 197
Flue gas mass flow, g/s 22,0
The dimension of the duct connection opening, mm E 1910
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Jaani T V1 21

Top connection

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1110
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 46,8
Nominal power (min-max), kW 2,0
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 13,2
Firewood consumption, kg/h 4,9
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2,6
Heat release time (h) 50% 13,6
Heat release time (h) 25% 24,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 100
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 500
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 164
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 197
Flue gas mass flow, g/s 22,0
The dimension of the duct connection opening, mm E 1910
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Jaani V1 15

Connection below

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 800
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 32,2
Nominal power (min-max), kW 1,7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4,5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12,1
Heat release time (h) 25% 18,6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 150
Safety distances front (dP), mm 900
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Cooking products Optional

Jaani V1 15

Connection below

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 800
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 32,2
Nominal power (min-max), kW 1,7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4,5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12,1
Heat release time (h) 25% 18,6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 150
Safety distances front (dP), mm 900
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Cooking products Optional

Jaani V1 18

Connection below

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 39,5
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 4,8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2,3
Heat release time (h) 50% 12,9
Heat release time (h) 25% 21,6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 150
Safety distances front (dP), mm 900
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Cooking products Optional

Jaani V1 18

Connection below

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 39,5
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 4,8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2,3
Heat release time (h) 50% 12,9
Heat release time (h) 25% 21,6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 150
Safety distances front (dP), mm 900
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Cooking products Optional

Jaani V1 21

Connection below

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1100
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 46,8
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13,2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2,6
Heat release time (h) 50% 13,6
Heat release time (h) 25% 24,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 150
Safety distances front (dP), mm 900
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227
Flue gas mass flow, g/s 22,0
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Cooking products Optional

Jaani V1 21

Connection below

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1100
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 46,8
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13,2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2,6
Heat release time (h) 50% 13,6
Heat release time (h) 25% 24,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 150
Safety distances front (dP), mm 900
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 225
Flue gas mass flow, g/s 22,0
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Cooking products Optional

Jaani T V1 15

Top connection

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 800
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32,2
Nominal power (min-max), kW 1,8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4,4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12,1
Heat release time (h) 25% 18,6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 100
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 16,7

Supplies

Ignition damper Standard equipment
Cooking products Optional

Jaani T V1 15

Top connection

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 800
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32,2
Nominal power (min-max), kW 1,8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4,4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12,1
Heat release time (h) 25% 18,6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 100
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 16,7

Supplies

Ignition damper Standard equipment
Cooking products Optional

Jaani T V1 18

Top connection

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 960
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39,5
Nominal power (min-max), kW 1,9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 4,7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2,3
Heat release time (h) 50% 12,9
Heat release time (h) 25% 21,6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 100
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm 100
Side radiation area (dL), mm 450
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0
The dimension of the duct connection opening, mm E 1540
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download