Aava KTU V2

Material

Aava KTU V2

1600 Matt Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Glossy White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Marble Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Glossy Marble White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Latte Coffee Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Glossy Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Chocolate Brown Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Mat White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Zinc Gray Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Matt Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Mat White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1600 Graphite Gray Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Marble Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Matt Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1600 Glossy White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Latte Coffee Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Marble Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1600 Glossy Marble White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Chocolate Brown Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Latte Coffee Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1600 Glossy Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Zinc Gray Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Chocolate Brown Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Mat White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1900 Graphite Gray Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Zinc Gray Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Matt Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1900 Glossy White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Graphite Gray Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Marble Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1900 Glossy Marble White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Glossy White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Latte Coffee Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1900 Glossy Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Glossy Marble White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Chocolate Brown Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Glossy Black Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Zinc Gray Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Material

Aava KTU V2

1600 Mat White Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

9 kg

Area to be heated

20-50 m2

Energy intensity

33,7 kWh

Material

Aava KTU V2

1900 Graphite Gray Rubbing, Ceramic

Efficiency

78 %

Maximum amount of wood

11,1 kg

Area to be heated

30-70 m2

Energy intensity

37 kWh

Surface material

Plaster surface

Height

Technical specifications

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 16

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1600
Weight, kg 820
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 33,7
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 9
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 800
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1450
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Aava KTU T V2 19

Top connection

Dimensions

Width, mm 800
Depth, mm 828
Height, mm 1900
Weight, kg 950
Firebox width, mm 310
Firebox depth, mm 380

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 37
Nominal power (min-max), kW 1,6
Efficiency, % 78
CO, mg/Nm3 1034
Particles, mg/Nm3 40
OGC, mg/Nm3 118
NOx, mg/Nm3 157
Maximum amount of wood, kg 11,1
Firewood consumption, kg/h 5,3
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 5
Heat release time (h) 50% 13,9
Heat release time (h) 25% 20,8

Safety distances

Safety distances back (dR), mm 50 (0)
Safety distances side (dS), mm 50
Safety distances up, mm 50
Safety distances front (dP), mm 850
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm -

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Top connection, mm 150
Maximum weight of top connection flue, kg 750
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 193
Max. flue gas temperature °C 338
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 232
The dimension of the duct connection opening, mm E 1705
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Standard equipment
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download