Technical information

Surface material

Plaster surface

Height

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A
Area to be heated, m2 20-50
Energy intensity, kWh 30
Nominal power (min-max), kW 1.7
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 204
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 245
Flue gas mass flow, g/s 16,7

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1500
Weight, kg 820

Heat technology

Energy sign A+
Area to be heated, m2 20-50
Energy intensity, kWh 32.2
Nominal power (min-max), kW 1.8
Efficiency, % 83
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 128
Maximum amount of wood, kg 9
Firewood consumption, kg/h 4.4
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2
Heat release time (h) 50% 12.1
Heat release time (h) 25% 18.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 800
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 173
Max. flue gas temperature °C 299
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 208
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 970

Heat technology

Energy sign A
Area to be heated, m2 30-70
Energy intensity, kWh 36.1
Nominal power (min-max), kW 1,6
Efficiency, % 79
CO, mg/Nm3 1125
Particles, mg/Nm3 35
OGC, mg/Nm3 39
NOx, mg/Nm3 103
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.8
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 197
Max. flue gas temperature °C 346
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 236
Flue gas mass flow, g/s 22,0

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 1800
Weight, kg 980

Heat technology

Energy sign A+
Area to be heated, m2 30-70
Energy intensity, kWh 39.5
Nominal power (min-max), kW 1.9
Efficiency, % 82
CO, mg/Nm3 1250
Particles, mg/Nm3 32
OGC, mg/Nm3 48
NOx, mg/Nm3 124
Maximum amount of wood, kg 11.1
Firewood consumption, kg/h 4.7
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.3
Heat release time (h) 50% 12.9
Heat release time (h) 25% 21.6
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 850
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 360
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,0

Supplies

Ignition damper Standard equipment
Cooking products Option

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1120

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 44.4
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13.2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.6
Heat release time (h) 50% 13.6
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1120

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 44.4
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13.2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.6
Heat release time (h) 50% 13.6
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1120

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 44.4
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13.2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.6
Heat release time (h) 50% 13.6
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1120

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 44.4
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13.2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.6
Heat release time (h) 50% 13.6
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1120

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 44.4
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13.2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.6
Heat release time (h) 50% 13.6
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1120

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 44.4
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13.2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.6
Heat release time (h) 50% 13.6
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1120

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 44.4
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13.2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.6
Heat release time (h) 50% 13.6
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1120

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 44.4
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13.2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.6
Heat release time (h) 50% 13.6
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 189
Max. flue gas temperature °C 316
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 227

Supplies

Cooking products Option

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 800
Depth, mm 600 (650)
Height, mm 2100
Weight, kg 1120

Heat technology

Energy sign A+
Area to be heated, m2 40-80
Energy intensity, kWh 44.4
Nominal power (min-max), kW 1,5
Efficiency, % 83
CO, mg/Nm3 1000
Particles, mg/Nm3 24
OGC, mg/Nm3 27
NOx, mg/Nm3 143
Maximum amount of wood, kg 13.2
Firewood consumption, kg/h 5
Length of firewood, mm 250 (200-330)
Heat release time (h) 100% 2.6
Heat release time (h) 50% 13.6
Heat release time (h) 25% 24.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 50 (0)
Safety distances side, mm 50
Safety distances up, mm 100
Safety distances front, mm 900
Safety distance shown in parentheses (0 mm) when installed against the wall with additional elements.

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…180