TU2200/92

Material

TU2200/92

60.2 Classic Soapstone

Efficiency

87 %

Maximum amount of wood, lbs

28.7 kg

Heated area, sq ft

450-1100

Material

TU2200/92

60.2 Classic Soapstone

Efficiency

87 %

Maximum amount of wood, lbs

28.7 kg

Heated area, sq ft

40-100

Technical specifications

TU2200/92

Chimney connection base

Dimensions (measurements on drawings below are in millimeters)

Width (inches) 40.2
Depth (inches) 23.6
Height (inches) 60.2
Weight (pounds) 3814
Firebox width (inches) 15.7
Firebox depth (inches) 14.4

Heating performance

Energy class A+
Heated area, sq ft (depending on heating requirements) 450-1100
Nominal heat output, kW 2.3
Efficiency % LHV 87
Maximum load of wood per 24 hours, lbs 28.7
Heat release time at 100%, in hours (this is how long the heater stays at its hottest) 4.4
Heat release time at 50%, in hours (this how long the heater stays above 50% of its hottest) 17.5
Heat release time at 25%, in hours (this how long the heater stays above 25% of its hottest; aka T25) 26.2

Safety distances to combustibles

Safety distance, back, inches (can be reduced to 3" with a UL/ULC specified heat shield) 20
Safety distance, sides, inches (can be reduced to 3" with a UL/ULC specified heat shield) 14
Safety distance, top (inches) 10
Safety distance, front (inches) 48
Satety distance to the side wall in front of the product (dL), mm

Chimney connection and combustion air information

Recommended flue diameter, inches 7-8

TU2200T/92

Top Connection

Dimensions (measurements on drawings below are in millimeters)

Width (inches) 40.2
Depth (inches) 23.6
Height (inches) 60.2
Weight (pounds) 3814
Firebox width (inches) 15.7
Firebox depth (inches) 14.4

Heating performance

Energy class A+
Heated area, sq ft (depending on heating requirements) 40-100
Nominal heat output, kW 2.5
Efficiency % LHV 87
Maximum load of wood per 24 hours, lbs 28.7
Heat release time at 100%, in hours (this is how long the heater stays at its hottest) 4.3
Heat release time at 50%, in hours (this how long the heater stays above 50% of its hottest) 14.4
Heat release time at 25%, in hours (this how long the heater stays above 25% of its hottest; aka T25) 25.1

Safety distances to combustibles

Safety distance, back, inches (can be reduced to 3" with a UL/ULC specified heat shield) 20
Safety distance, sides, inches (can be reduced to 3" with a UL/ULC specified heat shield) 14
Safety distance, top (inches) 10
Safety distance, front (inches) 48
Satety distance to the side wall in front of the product (dL), mm

Chimney connection and combustion air information

Recommended flue diameter, inches 7-8

Instructions & files

User manual LATAA
DXF Footprint (for architects) LATAA