Akko 2D

Material

Akko 2D

1935 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Material

Akko 2D

1935 Natural Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Material

Akko 2D

1935 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Material

Akko 2D

1935 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Material

Akko 2D

2235 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

2235 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

2235 Natural Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

2235 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

2235 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

2235 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

1935 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Material

Akko 2D

2235 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

1935 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Material

Akko 2D

2235 Natural Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

1935 Natural Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Material

Akko 2D

2235 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

1935 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Material

Akko 2D

2235 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Akko 2D

1935 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Material

Akko 2D

1935 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

55-80 m2

Energy intensity

48,3 kWh

Technical specifications

Akko 2D 18

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1860
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Akko 2D 18

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1860
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Akko 2D 18

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1860
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Akko 2D 18

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1860
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Akko 2D 21

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2300
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 21

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2300
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 21

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2300
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 21

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2300
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 21

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2300
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 21

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2140
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Akko 2D 18

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1960
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 21

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2140
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Akko 2D 18

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1960
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 21

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2140
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Akko 2D 18

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1960
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 21

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2140
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Akko 2D 18

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1960
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 21

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 2235
Weight, kg 2140
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Akko 2D 18

Connection below

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1960
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Akko 2D 18

Top connection

Dimensions

Width, mm 1100(1250)
Depth, mm 550(610)
Height, mm 1935
Weight, kg 1860
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1125
Particles, mg/Nm3 40
OGC, mg/Nm3 43
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download