Lampo

Material

Lampo

2145 Unica Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Lampo

1545 Classic Soapstone

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Lampo

2145 Classic Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Lampo

1545 Grafia Soapstone

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Lampo

2145 Grafia Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Lampo

1545 Nobile Soapstone

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Lampo

2145 Nobile Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Lampo

1545 Unica Soapstone

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Lampo

2145 Unica Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Lampo

1845 Classic Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Lampo

1845 Grafia Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Lampo

1845 Nobile Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Lampo

1845 Unica Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Lampo

1845 Classic Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Lampo

1845 Grafia Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Lampo

1845 Nobile Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Lampo

1845 Unica Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Lampo

2145 Classic Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Lampo

2145 Grafia Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Lampo

2145 Nobile Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Technical specifications

Lampo 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2145
Weight, kg 1950
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1545
Weight, kg 1360
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2145
Weight, kg 1830
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Lampo 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1545
Weight, kg 1360
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2145
Weight, kg 1830
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Lampo 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1545
Weight, kg 1360
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2145
Weight, kg 1830
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Lampo 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1545
Weight, kg 1360
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2145
Weight, kg 1830
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Lampo 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1845
Weight, kg 1650
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1845
Weight, kg 1650
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1845
Weight, kg 1650
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1845
Weight, kg 1650
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1845
Weight, kg 1570
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Lampo 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1845
Weight, kg 1570
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Lampo 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1845
Weight, kg 1570
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Lampo 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1845
Weight, kg 1570
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Lampo 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2145
Weight, kg 1950
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2145
Weight, kg 1950
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Lampo 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2145
Weight, kg 1950
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download