Salvo

Material

Salvo

2145 Grafia Soapstone

Efficiency

85,3 %

Maximum amount of wood

19 kg

Area to be heated

60-90 m2

Energy intensity

67,3 kWh

Material

Salvo

2145 Nobile Soapstone

Efficiency

85,3 %

Maximum amount of wood

19 kg

Area to be heated

60-90 m2

Energy intensity

67,3 kWh

Material

Salvo

2145 Unica Soapstone

Efficiency

85,3 %

Maximum amount of wood

19 kg

Area to be heated

60-90 m2

Energy intensity

67,3 kWh

Material

Salvo

1545 Classic Soapstone

Efficiency

84 %

Maximum amount of wood

12 kg

Area to be heated

50-70 m2

Energy intensity

41,9 kWh

Material

Salvo

2145 Classic Soapstone

Efficiency

85,3 %

Maximum amount of wood

19 kg

Area to be heated

60-90 m2

Energy intensity

67,3 kWh

Material

Salvo

1545 Grafia Soapstone

Efficiency

84 %

Maximum amount of wood

12 kg

Area to be heated

50-70 m2

Energy intensity

41,9 kWh

Material

Salvo

2145 Grafia Soapstone

Efficiency

85,3 %

Maximum amount of wood

19 kg

Area to be heated

60-90 m2

Energy intensity

67,3 kWh

Material

Salvo

1545 Nobile Soapstone

Efficiency

84 %

Maximum amount of wood

12 kg

Area to be heated

50-70 m2

Energy intensity

41,9 kWh

Material

Salvo

2145 Nobile Soapstone

Efficiency

85,3 %

Maximum amount of wood

19 kg

Area to be heated

60-90 m2

Energy intensity

67,3 kWh

Material

Salvo

1545 Unica Soapstone

Efficiency

84 %

Maximum amount of wood

12 kg

Area to be heated

50-70 m2

Energy intensity

41,9 kWh

Material

Salvo

2145 Unica Soapstone

Efficiency

85,3 %

Maximum amount of wood

19 kg

Area to be heated

60-90 m2

Energy intensity

67,3 kWh

Material

Salvo

1845 Classic Soapstone

Efficiency

84 %

Maximum amount of wood

15 kg

Area to be heated

55-80 m2

Energy intensity

52,6 kWh

Material

Salvo

1845 Grafia Soapstone

Efficiency

84 %

Maximum amount of wood

15 kg

Area to be heated

55-80 m2

Energy intensity

52,6 kWh

Material

Salvo

1845 Nobile Soapstone

Efficiency

84 %

Maximum amount of wood

15 kg

Area to be heated

55-80 m2

Energy intensity

52,6 kWh

Material

Salvo

1845 Unica Soapstone

Efficiency

84 %

Maximum amount of wood

15 kg

Area to be heated

55-80 m2

Energy intensity

52,6 kWh

Material

Salvo

1845 Classic Soapstone

Efficiency

84 %

Maximum amount of wood

15 kg

Area to be heated

55-80 m2

Energy intensity

52,6 kWh

Material

Salvo

1845 Grafia Soapstone

Efficiency

84 %

Maximum amount of wood

15 kg

Area to be heated

55-80 m2

Energy intensity

52,6 kWh

Material

Salvo

1845 Nobile Soapstone

Efficiency

84 %

Maximum amount of wood

15 kg

Area to be heated

55-80 m2

Energy intensity

52,6 kWh

Material

Salvo

1845 Unica Soapstone

Efficiency

84 %

Maximum amount of wood

15 kg

Area to be heated

55-80 m2

Energy intensity

52,6 kWh

Material

Salvo

2145 Classic Soapstone

Efficiency

85,3 %

Maximum amount of wood

19 kg

Area to be heated

60-90 m2

Energy intensity

67,3 kWh

Technical specifications

Salvo 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2145
Weight, kg 2160
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 67,3
Nominal power (min-max), kW 2,1
Efficiency, % 85,3
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 19
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 15
Heat release time (h) 100% 6,7
Heat release time (h) 50% 22,4
Heat release time (h) 25% 39,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 183
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 220
Flue gas mass flow, g/s 23,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional
Cooking products Optional

Salvo 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2145
Weight, kg 2160
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 67,3
Nominal power (min-max), kW 2,1
Efficiency, % 85,3
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 19
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 15
Heat release time (h) 100% 6,7
Heat release time (h) 50% 22,4
Heat release time (h) 25% 39,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 183
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 220
Flue gas mass flow, g/s 23,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional
Cooking products Optional

Salvo 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2145
Weight, kg 2160
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 67,3
Nominal power (min-max), kW 2,1
Efficiency, % 85,3
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 19
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 15
Heat release time (h) 100% 6,7
Heat release time (h) 50% 22,4
Heat release time (h) 25% 39,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 183
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 220
Flue gas mass flow, g/s 23,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional
Cooking products Optional

Salvo 15

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1545
Weight, kg 1500
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 41,9
Nominal power (min-max), kW 1,9
Efficiency, % 84
CO, mg/Nm3 1125
Particles, mg/Nm3 33
OGC, mg/Nm3 66
NOx, mg/Nm3 137
Maximum amount of wood, kg 12
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 6,1
Heat release time (h) 50% 18,1
Heat release time (h) 25% 28,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 289
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Salvo 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2145
Weight, kg 2030
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 67,3
Nominal power (min-max), kW 2,1
Efficiency, % 85,3
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 19
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 15
Heat release time (h) 100% 6,7
Heat release time (h) 50% 22,4
Heat release time (h) 25% 39,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 183
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 220
Flue gas mass flow, g/s 23,6
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Salvo 15

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1545
Weight, kg 1500
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 41,9
Nominal power (min-max), kW 1,9
Efficiency, % 84
CO, mg/Nm3 1125
Particles, mg/Nm3 33
OGC, mg/Nm3 66
NOx, mg/Nm3 137
Maximum amount of wood, kg 12
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 6,1
Heat release time (h) 50% 18,1
Heat release time (h) 25% 28,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 289
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Salvo 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2145
Weight, kg 2030
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 67,3
Nominal power (min-max), kW 2,1
Efficiency, % 85,3
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 19
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 15
Heat release time (h) 100% 6,7
Heat release time (h) 50% 22,4
Heat release time (h) 25% 39,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 183
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 220
Flue gas mass flow, g/s 23,6
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Salvo 15

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1545
Weight, kg 1500
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 41,9
Nominal power (min-max), kW 1,9
Efficiency, % 84
CO, mg/Nm3 1125
Particles, mg/Nm3 33
OGC, mg/Nm3 66
NOx, mg/Nm3 137
Maximum amount of wood, kg 12
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 6,1
Heat release time (h) 50% 18,1
Heat release time (h) 25% 28,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 289
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Salvo 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2145
Weight, kg 2030
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 67,3
Nominal power (min-max), kW 2,1
Efficiency, % 85,3
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 19
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 15
Heat release time (h) 100% 6,7
Heat release time (h) 50% 22,4
Heat release time (h) 25% 39,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 183
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 220
Flue gas mass flow, g/s 23,6
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Salvo 15

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1545
Weight, kg 1500
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 41,9
Nominal power (min-max), kW 1,9
Efficiency, % 84
CO, mg/Nm3 1125
Particles, mg/Nm3 33
OGC, mg/Nm3 66
NOx, mg/Nm3 137
Maximum amount of wood, kg 12
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 6,1
Heat release time (h) 50% 18,1
Heat release time (h) 25% 28,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 167
Max. flue gas temperature °C 289
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 200
Flue gas mass flow, g/s 22,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Salvo 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2145
Weight, kg 2030
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 67,3
Nominal power (min-max), kW 2,1
Efficiency, % 85,3
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 19
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 15
Heat release time (h) 100% 6,7
Heat release time (h) 50% 22,4
Heat release time (h) 25% 39,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 183
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 220
Flue gas mass flow, g/s 23,6
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Salvo 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1845
Weight, kg 1830
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 52,6
Nominal power (min-max), kW 2,0
Efficiency, % 84
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 15
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 6,4
Heat release time (h) 50% 19,9
Heat release time (h) 25% 33,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 23,4
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional
Cooking products Optional

Salvo 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1845
Weight, kg 1830
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 52,6
Nominal power (min-max), kW 2,0
Efficiency, % 84
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 15
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 6,4
Heat release time (h) 50% 19,9
Heat release time (h) 25% 33,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 23,4
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional
Cooking products Optional

Salvo 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1845
Weight, kg 1830
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 52,6
Nominal power (min-max), kW 2,0
Efficiency, % 84
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 15
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 6,4
Heat release time (h) 50% 19,9
Heat release time (h) 25% 33,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 23,4
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional
Cooking products Optional

Salvo 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1845
Weight, kg 1830
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 52,6
Nominal power (min-max), kW 2,0
Efficiency, % 84
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 15
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 6,4
Heat release time (h) 50% 19,9
Heat release time (h) 25% 33,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 23,4
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional
Cooking products Optional

Salvo 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1845
Weight, kg 1760
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 52,6
Nominal power (min-max), kW 2,0
Efficiency, % 84
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 15
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 6,4
Heat release time (h) 50% 19,9
Heat release time (h) 25% 33,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 23,4
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Salvo 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1845
Weight, kg 1760
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 52,6
Nominal power (min-max), kW 2,0
Efficiency, % 84
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 15
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 6,4
Heat release time (h) 50% 19,9
Heat release time (h) 25% 33,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 23,4
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Salvo 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1845
Weight, kg 1760
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 52,6
Nominal power (min-max), kW 2,0
Efficiency, % 84
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 15
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 6,4
Heat release time (h) 50% 19,9
Heat release time (h) 25% 33,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 23,4
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Salvo 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1845
Weight, kg 1760
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 52,6
Nominal power (min-max), kW 2,0
Efficiency, % 84
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 15
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 6,4
Heat release time (h) 50% 19,9
Heat release time (h) 25% 33,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 175
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 210
Flue gas mass flow, g/s 23,4
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Salvo 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2145
Weight, kg 2160
Firebox width, mm 470
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 67,3
Nominal power (min-max), kW 2,1
Efficiency, % 85,3
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 19
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 15
Heat release time (h) 100% 6,7
Heat release time (h) 50% 22,4
Heat release time (h) 25% 39,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (250)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 183
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 220
Flue gas mass flow, g/s 23,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download