Koli 2D

Material

Koli 2D

1800 Grafia Soapstone

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Grafia Soapstone

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Nobile Soapstone

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Nobile Soapstone

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Unica Soapstone

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Unica Soapstone

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Lux White Ceramic

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Lux White Ceramic

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Satin White Ceramic

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Satin White Ceramic

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Structure White Ceramic

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Structure White Ceramic

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Structure Black Ceramic

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Structure Black Ceramic

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Classic Soapstone

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Classic Soapstone

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Grafia Soapstone

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Grafia Soapstone

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Nobile Soapstone

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Nobile Soapstone

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Unica Soapstone

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Unica Soapstone

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Lux White Ceramic

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Lux White Ceramic

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Satin White Ceramic

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Satin White Ceramic

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Structure White Ceramic

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Structure White Ceramic

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Structure Black Ceramic

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Structure Black Ceramic

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Material

Koli 2D

1800 Classic Soapstone

Efficiency

84 %

Maximum amount of wood

11,7 kg

Area to be heated

60-90 m2

Energy intensity

41,1 kWh

Material

Koli 2D

2100 Classic Soapstone

Efficiency

84 %

Maximum amount of wood

14,3 kg

Area to be heated

60-80 m2

Energy intensity

50,2 kWh

Technical specifications

Koli 2D 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1520
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1790
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1520
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1790
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1520
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1790
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1300
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1300
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1300
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1300
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1610
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1890
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1610
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1890
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1610
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1890
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1610
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1890
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1210
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1420
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1210
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1420
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1210
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1420
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1210
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1420
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 2D 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1520
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-90
Energy intensity, kWh 41,1
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 11,7
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 2D 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1790
Firebox width, mm 320
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 50,2
Nominal power (min-max), kW 1,0
Efficiency, % 84
CO, mg/Nm3 1000
Particles, mg/Nm3 34
OGC, mg/Nm3 53
NOx, mg/Nm3 163
Maximum amount of wood, kg 14,3
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,2
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (150)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 163
Max. flue gas temperature °C 298
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 196
Flue gas mass flow, g/s 24,1
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download