Koli

Material

Koli

1500 Classic Soapstone

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Koli

1800 Classic Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Classic Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1500 Grafia Soapstone

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Koli

1800 Grafia Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Grafia Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1500 Nobile Soapstone

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Koli

1800 Nobile Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Nobile Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1500 Unica Soapstone

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Koli

1800 Unica Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Unica Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1500 Lux White Ceramic

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Koli

1800 Lux White Ceramic

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Lux White Ceramic

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1500 Satin White Ceramic

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Koli

1800 Satin White Ceramic

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Satin White Ceramic

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1500 Structure White Ceramic

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Koli

1800 Structure White Ceramic

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Structure White Ceramic

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1500 Structure Black Ceramic

Efficiency

84 %

Maximum amount of wood

10 kg

Area to be heated

30-50 m2

Energy intensity

35,1 kWh

Material

Koli

1800 Structure Black Ceramic

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Structure Black Ceramic

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1800 Classic Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Classic Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1800 Grafia Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Grafia Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1800 Nobile Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Nobile Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1800 Unica Soapstone

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Unica Soapstone

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1800 Lux White Ceramic

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Lux White Ceramic

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1800 Satin White Ceramic

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Satin White Ceramic

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1800 Structure White Ceramic

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Structure White Ceramic

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Material

Koli

1800 Structure Black Ceramic

Efficiency

85 %

Maximum amount of wood

13 kg

Area to be heated

50-70 m2

Energy intensity

45,4 kWh

Material

Koli

2100 Structure Black Ceramic

Efficiency

86 %

Maximum amount of wood

16 kg

Area to be heated

60-80 m2

Energy intensity

57,6 kWh

Technical specifications

Koli 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1340
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1800
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1340
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1800
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1340
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1800
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1340
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1800
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1010
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1310
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1010
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1310
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1010
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1310
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 15

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1010
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35,1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8,3
Heat release time (h) 100% 6
Heat release time (h) 50% 20,4
Heat release time (h) 25% 32,8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 21

Top connection

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1310
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Koli 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1640
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1920
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1640
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1920
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1640
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1920
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1640
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1920
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1220
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1220
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1220
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 18

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1220
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45,4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10,4
Heat release time (h) 100% 6,9
Heat release time (h) 50% 23
Heat release time (h) 25% 38,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Koli 21

Connection below

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57,6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12,5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45,1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 20 (100)
Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1000
Safety distances down, mm 0
Safety distance to the side on the front of the product (dS2), mm 150
Side radiation area (dL), mm 700
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download