Technical information

Height

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1340
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35.1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8.3
Heat release time (h) 100% 6
Heat release time (h) 50% 20.4
Heat release time (h) 25% 32.8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1220
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1340
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35.1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8.3
Heat release time (h) 100% 6
Heat release time (h) 50% 20.4
Heat release time (h) 25% 32.8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1220
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1340
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35.1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8.3
Heat release time (h) 100% 6
Heat release time (h) 50% 20.4
Heat release time (h) 25% 32.8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1340
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35.1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8.3
Heat release time (h) 100% 6
Heat release time (h) 50% 20.4
Heat release time (h) 25% 32.8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1010
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35.1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8.3
Heat release time (h) 100% 6
Heat release time (h) 50% 20.4
Heat release time (h) 25% 32.8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1800
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1010
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35.1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8.3
Heat release time (h) 100% 6
Heat release time (h) 50% 20.4
Heat release time (h) 25% 32.8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1550
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1800
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1010
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35.1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8.3
Heat release time (h) 100% 6
Heat release time (h) 50% 20.4
Heat release time (h) 25% 32.8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1800
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1010
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35.1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8.3
Heat release time (h) 100% 6
Heat release time (h) 50% 20.4
Heat release time (h) 25% 32.8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1800
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1500
Weight, kg 1010
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 30-50
Energy intensity, kWh 35.1
Nominal power (min-max), kW 1,3
Efficiency, % 84
CO, mg/Nm3 1250
Particles, mg/Nm3 38
OGC, mg/Nm3 52
NOx, mg/Nm3 153
Maximum amount of wood, kg 10
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 8.3
Heat release time (h) 100% 6
Heat release time (h) 50% 20.4
Heat release time (h) 25% 32.8
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 150 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 129
Max. flue gas temperature °C 260
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 155
Flue gas mass flow, g/s 21,1

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1310
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1640
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1310
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1640
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1120
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1310
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1640
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1920
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1310
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1640
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1920
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1310
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Other considerations

E = maximum dimension for the upper edge of the chimney opening from the floor from the top back at the connection (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1220
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1920
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1220
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1920
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 1800
Weight, kg 1220
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 45.4
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 1250
Particles, mg/Nm3 35
OGC, mg/Nm3 64
NOx, mg/Nm3 153
Maximum amount of wood, kg 13
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 10.4
Heat release time (h) 100% 6.9
Heat release time (h) 50% 23
Heat release time (h) 25% 38.5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 131
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 157
Flue gas mass flow, g/s 19,6

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)

Dimensions

Width, mm 950
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 320
Firebox depth, mm 345

Heat technology

Energy sign A+
Area to be heated, m2 60-80
Energy intensity, kWh 57.6
Nominal power (min-max), kW 1,6
Efficiency, % 86
CO, mg/Nm3 1250
Particles, mg/Nm3 31
OGC, mg/Nm3 79
NOx, mg/Nm3 154
Maximum amount of wood, kg 16
Length of firewood, mm 250 (200-330)
Maximum amount of pellets, kg 12.5
Heat release time (h) 100% 8
Heat release time (h) 50% 26
Heat release time (h) 25% 45.1
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back, mm 20 (100)
Safety distances side, mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front, mm 1000
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 134
Max. flue gas temperature °C 213
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 161
Flue gas mass flow, g/s 17,8

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Other considerations

A = Width of the chimney opening (mm), B = maximum dimension for the upper edge of the chimney opening from the floor (mm), C = minimum dimension for the lower edge of the chimney opening from the floor (mm)