Raita 2D

Material

Raita 2D

1800 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Classic Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Structure White Ceramic

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

2100 Structure Black Ceramic

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Classic Soapstone

Efficiency

85 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Grafia Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Grafia Soapstone

Efficiency

85 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Nobile Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Nobile Soapstone

Efficiency

85 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Unica Soapstone

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Unica Soapstone

Efficiency

85 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Lux White Ceramic

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Material

Raita 2D

1800 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

14 kg

Area to be heated

50-70 m2

Energy intensity

48,3 kWh

Material

Raita 2D

2100 Satin White Ceramic

Efficiency

83 %

Maximum amount of wood

17 kg

Area to be heated

55-80 m2

Energy intensity

58,7 kWh

Technical specifications

Raita 2D 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1340
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1590
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1340
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1590
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1680
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1960
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1680
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1960
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1680
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1960
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1680
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1960
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1240
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1240
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1240
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1240
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1600
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Top connection

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1430
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Top connection, mm 150
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm E 1900
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1780
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Raita 2D 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 2120
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Raita 2D 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1780
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Raita 2D 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 2120
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Raita 2D 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1780
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Raita 2D 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 2120
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Raita 2D 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1780
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Raita 2D 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 2120
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 85
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Electrical resistors Optional
Cooking products Optional

Raita 2D 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1340
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1590
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 18

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 1800
Weight, kg 1340
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 50-70
Energy intensity, kWh 48,3
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 1021
Particles, mg/Nm3 35
OGC, mg/Nm3 53
NOx, mg/Nm3 139
Maximum amount of wood, kg 14
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 10,8
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Ignition damper Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Raita 2D 21

Connection below

Dimensions

Width, mm 1100
Depth, mm 550
Height, mm 2100
Weight, kg 1590
Firebox width, mm 470
Firebox depth, mm 490

Heat technology

Energy sign A+
Area to be heated, m2 55-80
Energy intensity, kWh 58,7
Nominal power (min-max), kW 1,4
Efficiency, % 83
CO, mg/Nm3 875
Particles, mg/Nm3 38
OGC, mg/Nm3 35
NOx, mg/Nm3 143
Maximum amount of wood, kg 17
Length of firewood, mm 330 (200-330)
Maximum amount of pellets, kg 14,1
Heat release time (h) 100% 6,6
Heat release time (h) 50% 22,2
Heat release time (h) 25% 39,4
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances side (dS), mm 50 (100)
Safety distances up, mm 100 (150)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm 450
Side radiation area (dL), mm 850
Safety distance for uninsulated product shown in parentheses (XX mm)

Chimney connection and combustion air information

Chimney recommendation, ø mm 150…210
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 187
Max. flue gas temperature °C 230
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 224
Flue gas mass flow, g/s 30,3
The dimension of the duct connection opening, mm B 370
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

P10-Pellet system Standard equipment
Senso fireplace controller Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download