Mella 3G

New
Material

Mella 3G

1450 Nobile Soapstone

Efficiency

83 %

Area to be heated

40-120 m2

New
Material

Mella 3G

1450 Unica Soapstone

Efficiency

83 %

Area to be heated

40-120 m2

New
Material

Mella 3G

1900 Classic Soapstone

Efficiency

83 %

Area to be heated

40-120 m2

New
Material

Mella 3G

1900 Grafia Soapstone

Efficiency

83 %

Area to be heated

40-120 m2

New
Material

Mella 3G

1900 Nobile Soapstone

Efficiency

83 %

Area to be heated

40-120 m2

New
Material

Mella 3G

1900 Unica Soapstone

Efficiency

83 %

Area to be heated

40-120 m2

New
Material

Mella 3G

1450 Classic Soapstone

Efficiency

83 %

Area to be heated

40-120 m2

New
Material

Mella 3G

1450 Grafia Soapstone

Efficiency

83 %

Area to be heated

40-120 m2

Technical specifications

Mella 3G 14

Top connection

Dimensions

Width, mm 900
Depth, mm 600
Height, mm 1450
Weight, kg 680
Firebox width, mm 610
Firebox depth, mm 330

Heat technology

Energy sign A+
Area to be heated, m2 40-120
Nominal power (min-max), kW 9,5
Efficiency, % 83
CO, mg/Nm3 ≤ 1500
Particles, mg/Nm3 ≤ 40
OGC, mg/Nm3 ≤ 120
NOx, mg/Nm3 ≤ 200
Firewood consumption, kg/h 2,7
Length of firewood, mm 250
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 400 (50)
Safety distances side (dS), mm 300 (155)
Safety distances up, mm 600 (600)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm 580 (400)
The safety distance for the product with the heat shield is shown in parentheses (XX mm). The heat shield is an accessory.

Chimney connection and combustion air information

Chimney recommendation, ø mm 180…210
Top connection, mm 180
Maximum weight of top connection flue, kg 120
Fire air intake from under the floor, connection size, ø mm 125
Average flue gas temperature °C 261
Max. flue gas temperature °C 418
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 284
Flue gas mass flow, g/s 7,3

Supplies

Additional heat storage mass: 1 x 21 kg + 1 x 65 kg Optional

Mella 3G 14

Top connection

Dimensions

Width, mm 900
Depth, mm 600
Height, mm 1450
Weight, kg 680
Firebox width, mm 610
Firebox depth, mm 330

Heat technology

Energy sign A+
Area to be heated, m2 40-120
Nominal power (min-max), kW 9,5
Efficiency, % 83
CO, mg/Nm3 ≤ 1500
Particles, mg/Nm3 ≤ 40
OGC, mg/Nm3 ≤ 120
NOx, mg/Nm3 ≤ 200
Firewood consumption, kg/h 2,7
Length of firewood, mm 250
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 400 (50)
Safety distances side (dS), mm 300 (155)
Safety distances up, mm 600 (600)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm 580 (400)
The safety distance for the product with the heat shield is shown in parentheses (XX mm). The heat shield is an accessory.

Chimney connection and combustion air information

Chimney recommendation, ø mm 180…210
Top connection, mm 180
Maximum weight of top connection flue, kg 120
Fire air intake from under the floor, connection size, ø mm 125
Average flue gas temperature °C 261
Max. flue gas temperature °C 418
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 284
Flue gas mass flow, g/s 7,3

Supplies

Additional heat storage mass: 1 x 21 kg + 1 x 65 kg Optional

Mella 3G 18

Top Connection, Back Top Connection, Side Connection from Above

Dimensions

Width, mm 900
Depth, mm 600
Height, mm 1900
Weight, kg 830
Firebox width, mm 610
Firebox depth, mm 330

Heat technology

Energy sign A+
Area to be heated, m2 40-120
Nominal power (min-max), kW 9,5
Efficiency, % 83
CO, mg/Nm3 ≤ 1500
Particles, mg/Nm3 ≤ 40
OGC, mg/Nm3 ≤ 120
NOx, mg/Nm3 ≤ 200
Firewood consumption, kg/h 2,7
Length of firewood, mm 250
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 400 (50)
Safety distances side (dS), mm 300 (155)
Safety distances up, mm 600 (600)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm 580 (400)
The safety distance for the product with the heat shield is shown in parentheses (XX mm). The heat shield is an accessory.

Chimney connection and combustion air information

Chimney recommendation, ø mm 180…210
Top connection, mm 180
Maximum weight of top connection flue, kg 120
Fire air intake from under the floor, connection size, ø mm 125
Average flue gas temperature °C 261
Max. flue gas temperature °C 418
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 284
Flue gas mass flow, g/s 7,3
The dimension of the duct connection opening, mm E 1674
E = measurement from the floor to the center of the flue opening at the back top flue connection (mm)

Supplies

Additional heat storage mass: 1 x 21 kg + 1 x 65 kg Optional

Mella 3G 18

Top Connection, Back Top Connection, Side Connection from Above

Dimensions

Width, mm 900
Depth, mm 600
Height, mm 1900
Weight, kg 830
Firebox width, mm 610
Firebox depth, mm 330

Heat technology

Energy sign A+
Area to be heated, m2 40-120
Nominal power (min-max), kW 9,5
Efficiency, % 83
CO, mg/Nm3 ≤ 1500
Particles, mg/Nm3 ≤ 40
OGC, mg/Nm3 ≤ 120
NOx, mg/Nm3 ≤ 200
Firewood consumption, kg/h 2,7
Length of firewood, mm 250
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 400 (50)
Safety distances side (dS), mm 300 (155)
Safety distances up, mm 600 (600)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm 580 (400)
The safety distance for the product with the heat shield is shown in parentheses (XX mm). The heat shield is an accessory.

Chimney connection and combustion air information

Chimney recommendation, ø mm 180…210
Top connection, mm 180
Maximum weight of top connection flue, kg 120
Fire air intake from under the floor, connection size, ø mm 125
Average flue gas temperature °C 261
Max. flue gas temperature °C 418
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 284
Flue gas mass flow, g/s 7,3
The dimension of the duct connection opening, mm E 1674
E = measurement from the floor to the center of the flue opening at the back top flue connection (mm)

Supplies

Additional heat storage mass: 1 x 21 kg + 1 x 65 kg Optional

Mella 3G 18

Top Connection, Back Top Connection, Side Connection from Above

Dimensions

Width, mm 900
Depth, mm 600
Height, mm 1900
Weight, kg 830
Firebox width, mm 610
Firebox depth, mm 330

Heat technology

Energy sign A+
Area to be heated, m2 40-120
Nominal power (min-max), kW 9,5
Efficiency, % 83
CO, mg/Nm3 ≤ 1500
Particles, mg/Nm3 ≤ 40
OGC, mg/Nm3 ≤ 120
NOx, mg/Nm3 ≤ 200
Firewood consumption, kg/h 2,7
Length of firewood, mm 250
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 400 (50)
Safety distances side (dS), mm 300 (155)
Safety distances up, mm 600 (600)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm 580 (400)
The safety distance for the product with the heat shield is shown in parentheses (XX mm). The heat shield is an accessory.

Chimney connection and combustion air information

Chimney recommendation, ø mm 180…210
Top connection, mm 180
Maximum weight of top connection flue, kg 120
Fire air intake from under the floor, connection size, ø mm 125
Average flue gas temperature °C 261
Max. flue gas temperature °C 418
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 284
Flue gas mass flow, g/s 7,3
The dimension of the duct connection opening, mm E 1674
E = measurement from the floor to the center of the flue opening at the back top flue connection (mm)

Supplies

Additional heat storage mass: 1 x 21 kg + 1 x 65 kg Optional

Mella 3G 18

Top Connection, Back Top Connection, Side Connection from Above

Dimensions

Width, mm 900
Depth, mm 600
Height, mm 1900
Weight, kg 830
Firebox width, mm 610
Firebox depth, mm 330

Heat technology

Energy sign A+
Area to be heated, m2 40-120
Nominal power (min-max), kW 9,5
Efficiency, % 83
CO, mg/Nm3 ≤ 1500
Particles, mg/Nm3 ≤ 40
OGC, mg/Nm3 ≤ 120
NOx, mg/Nm3 ≤ 200
Firewood consumption, kg/h 2,7
Length of firewood, mm 250
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 400 (50)
Safety distances side (dS), mm 300 (155)
Safety distances up, mm 600 (600)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm 580 (400)
The safety distance for the product with the heat shield is shown in parentheses (XX mm). The heat shield is an accessory.

Chimney connection and combustion air information

Chimney recommendation, ø mm 180…210
Top connection, mm 180
Maximum weight of top connection flue, kg 120
Fire air intake from under the floor, connection size, ø mm 125
Average flue gas temperature °C 261
Max. flue gas temperature °C 418
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 284
Flue gas mass flow, g/s 7,3
The dimension of the duct connection opening, mm E 1674
E = measurement from the floor to the center of the flue opening at the back top flue connection (mm)

Supplies

Additional heat storage mass: 1 x 21 kg + 1 x 65 kg Optional

Mella 3G 14

Top connection

Dimensions

Width, mm 900
Depth, mm 600
Height, mm 1450
Weight, kg 680
Firebox width, mm 610
Firebox depth, mm 330

Heat technology

Energy sign A+
Area to be heated, m2 40-120
Nominal power (min-max), kW 9,5
Efficiency, % 83
CO, mg/Nm3 ≤ 1500
Particles, mg/Nm3 ≤ 40
OGC, mg/Nm3 ≤ 120
NOx, mg/Nm3 ≤ 200
Firewood consumption, kg/h 2,7
Length of firewood, mm 250
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 400 (50)
Safety distances side (dS), mm 300 (155)
Safety distances up, mm 600 (600)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm 580 (400)
The safety distance for the product with the heat shield is shown in parentheses (XX mm). The heat shield is an accessory.

Chimney connection and combustion air information

Chimney recommendation, ø mm 180…210
Top connection, mm 180
Maximum weight of top connection flue, kg 120
Fire air intake from under the floor, connection size, ø mm 125
Average flue gas temperature °C 261
Max. flue gas temperature °C 418
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 284
Flue gas mass flow, g/s 7,3

Supplies

Additional heat storage mass: 1 x 21 kg + 1 x 65 kg Optional

Mella 3G 14

Top connection

Dimensions

Width, mm 900
Depth, mm 600
Height, mm 1450
Weight, kg 680
Firebox width, mm 610
Firebox depth, mm 330

Heat technology

Energy sign A+
Area to be heated, m2 40-120
Nominal power (min-max), kW 9,5
Efficiency, % 83
CO, mg/Nm3 ≤ 1500
Particles, mg/Nm3 ≤ 40
OGC, mg/Nm3 ≤ 120
NOx, mg/Nm3 ≤ 200
Firewood consumption, kg/h 2,7
Length of firewood, mm 250
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 400 (50)
Safety distances side (dS), mm 300 (155)
Safety distances up, mm 600 (600)
Safety distances front (dP), mm 1200
Safety distance to the side on the front of the product (dS2), mm -
Side radiation area (dL), mm 580 (400)
The safety distance for the product with the heat shield is shown in parentheses (XX mm). The heat shield is an accessory.

Chimney connection and combustion air information

Chimney recommendation, ø mm 180…210
Top connection, mm 180
Maximum weight of top connection flue, kg 120
Fire air intake from under the floor, connection size, ø mm 125
Average flue gas temperature °C 261
Max. flue gas temperature °C 418
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 284
Flue gas mass flow, g/s 7,3

Supplies

Additional heat storage mass: 1 x 21 kg + 1 x 65 kg Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download