TTU2700/8

Material

TTU2700/8

1830 Classic Soapstone

Efficiency

79 %

Maximum amount of wood

21,6 kg

Area to be heated

50-110 m2

Energy intensity

73,8 kWh

Material

TTU2700/8

1830 Classic Soapstone

Efficiency

79 %

Maximum amount of wood

21,6 kg

Area to be heated

50-110 m2

Energy intensity

73,8 kWh

Technical specifications

TTU2700/8

Top connection

Dimensions

Width, mm 1020
Depth, mm 750
Height, mm 1830
Weight, kg 2580
Firebox width, mm 400
Firebox depth, mm 365

Heat technology

Energy sign A
Area to be heated, m2 50-110
Energy intensity, kWh 73,8
Nominal power (min-max), kW 2,3
Efficiency, % 79
CO, mg/Nm3 836
Particles, mg/Nm3 37
OGC, mg/Nm3 25
NOx, mg/Nm3 164
Maximum amount of wood, kg 21,6
Firewood consumption, kg/h 11
Length of firewood, mm 330 (200-330)
Heat release time (h) 100% 5,2
Heat release time (h) 50% 21,3
Heat release time (h) 25% 32,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 100
Safety distances side (dS), mm 200
Safety distances up, mm 250
Safety distances front (dP), mm 1000

Chimney connection and combustion air information

Chimney recommendation, ø mm 150..180
Top connection, mm 175
Maximum weight of top connection flue, kg 550
Fire air intake from under the floor, connection size, ø mm 150
Average flue gas temperature °C 242
Max. flue gas temperature °C 404
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 290
Flue gas mass flow, g/s 38,4

Supplies

Ignition damper Optional
P10-Pellet system Optional
Electrical resistors Optional
Cooking products Optional

TTU2700/8

Connection below

Dimensions

Width, mm 1020
Depth, mm 750
Height, mm 1830
Weight, kg 2580
Firebox width, mm 400
Firebox depth, mm 365

Heat technology

Energy sign A
Area to be heated, m2 50-110
Energy intensity, kWh 73,8
Nominal power (min-max), kW 2,3
Efficiency, % 79
CO, mg/Nm3 836
Particles, mg/Nm3 37
OGC, mg/Nm3 25
NOx, mg/Nm3 164
Maximum amount of wood, kg 21,6
Firewood consumption, kg/h 11
Length of firewood, mm 330 (200-330)
Heat release time (h) 100% 5,2
Heat release time (h) 50% 21,3
Heat release time (h) 25% 32,5
Firewood length can vary between those shown in parentheses (XX mm)

Safety distances

Safety distances back (dR), mm 100
Safety distances side (dS), mm 200
Safety distances up, mm 250
Safety distances front (dP), mm 1000

Chimney connection and combustion air information

Chimney recommendation, ø mm 150..180
Average flue gas temperature °C 242
Max. flue gas temperature °C 404
Minimum draft of the flue, Pa. 12
Flue gas outlet temperature °C 290
Flue gas mass flow, g/s 38,4
The dimension of the duct connection opening, mm B 310
B = maximum dimension for the upper edge of the chimney opening from the floor (mm), E=The height of the flue connection measured from the floor to the center of the flue pipe.

Supplies

Ignition damper Optional
P10-Pellet system Optional
Electrical resistors Optional
Cooking products Optional

Instructions & files

Manual Download
DXF Footprint Download
Performance level declaration, Dop Download
Eco-design product information Download
Energy sign Download
Declaration of conformity Download